Insulation R-Value by Climate Zone: The Contractor's Reference

R-value requirements by IECC climate zone for walls, attics, floors, and basements. Updated for IECC 2021. A complete contractor reference guide.

One of the most common questions we get: "What R-value do I need for this job?" The answer depends entirely on your climate zone and the assembly type. This is the reference we wish existed when we started — zone-by-zone, assembly-by-assembly.

How climate zones work

The IECC (International Energy Conservation Code) divides the U.S. into 8 climate zones based on heating and cooling degree days. Zone 1 is the hottest (Miami), Zone 8 is the coldest (Fairbanks). Your local building department enforces the zone-specific requirements for your jurisdiction.

Wall R-values by climate zone (IECC 2021)

ZoneStates (sample)2×4 Wall2×6 Wall
1Hawaii, S. FloridaR-13R-19
2FL, S. TX, Puerto RicoR-13R-19
3TX, GA, AL, AZ, S. CAR-13 + R-3.75 ci (or R-15)R-19 or R-21
4VA, NC, TN, CO, WAR-15 + R-3.8 ci (or 2×6 R-19)R-21
5OH, IL, PA, NY, ORR-15 + R-7.5 ci (or 2×6 R-21)R-21 + R-3.8 ci
6MN, WI, MI, MT, northern NER-15 + R-7.5 ciR-21 + R-5 ci
7–8AK, far northern MNR-15 + R-10 ciR-21 + R-10 ci

ci = continuous insulation (exterior foam board). Without ci, 2×6 framing with R-21 HD is the practical alternative for zones 4–6.

Attic R-values by climate zone (IECC 2021)

ZoneAttic Floor MinimumRecommended
1–2R-30R-38
3R-38R-49
4R-38 to R-49R-49
5R-49R-49 to R-60
6–8R-49 to R-60R-60

Floor R-values by climate zone

ZoneFloor Over Crawl / Unconditioned
1–3R-13 to R-19
4–5R-19 to R-30
6–8R-30

Basement wall R-values

ZoneBelow-Grade Wall
1–3R-0 (not required)
4–8R-10 to R-15 continuous OR R-13 cavity + R-5 ci

For below-grade applications, mineral wool (R-15) is the preferred product — it's non-combustible, moisture-resistant, and handles the humidity conditions common in basement assemblies. See our mineral wool page →

Quick reference: what to order by zone

  • Zone 1–2: R-13 walls · R-30 attic · R-13 floor
  • Zone 3: R-15 HD walls (2×4) · R-21 (2×6) · R-38 attic · R-19 floor
  • Zone 4: R-15 HD or 2×6 R-21 · R-38–R-49 attic · R-19–R-30 floor
  • Zone 5: 2×6 R-21 + R-3.8 ci · R-49 attic · R-30 floor
  • Zone 6–8: 2×6 R-21 + R-5–10 ci · R-49–R-60 attic · R-30 floor