IECC Climate Zone Map: Which Zone Are You In?

The International Energy Conservation Code (IECC) divides the US into 8 climate zones. Your zone determines the minimum R-value required for each building assembly.

  • Zone 1: South Florida, Hawaii — Hot-Humid
  • Zone 2: Gulf Coast, Phoenix AZ, Houston TX — Hot-Humid/Dry
  • Zone 3: Atlanta GA, Dallas TX, Los Angeles CA — Warm
  • Zone 4: Washington DC, Kansas City MO, Seattle WA — Mixed
  • Zone 5: Chicago IL, Denver CO, Indianapolis IN — Cold
  • Zone 6: Minneapolis MN, Boston MA, Portland ME — Cold
  • Zone 7: Northern Minnesota, Northern Montana — Very Cold
  • Zone 8: Alaska — Subarctic

IECC 2021 Minimum R-Values by Zone

Exterior Walls (Wood Frame)

Climate Zone 2×4 Wall Min. 2×6 Wall Min. Recommended Product
Zone 1–2R-13R-19R-13 or R-15 (2×4), R-19 or R-21 (2×6)
Zone 3R-13R-20R-13 or R-15 (2×4), R-21 HD (2×6)
Zone 4R-15R-21R-15 HD (2×4), R-21 HD (2×6)
Zone 5R-20R-21R-21 HD (both)
Zone 6–8R-20R-21+R-21 HD + continuous insulation

Attic / Ceiling Insulation

Climate Zone Minimum R-Value Recommended Product
Zone 1–2R-30R-30 batts
Zone 3R-38R-38 batts
Zone 4R-38–R-49R-38 or R-49 batts
Zone 5R-49R-49 batts
Zone 6–8R-49–R-60R-49 batts + additional layer

Floor / Crawl Space Insulation

Climate Zone Over Unconditioned Space Conditioned Crawl Wall
Zone 1–3R-13R-5
Zone 4–5R-19R-10
Zone 6–8R-30R-15

Key Code Notes for Contractors

  • IECC 2021 wall change: Zones 4+ now require R-15 minimum for 2×4 exterior walls. R-13 is no longer code-minimum in zone 4. Many states have adopted IECC 2021 — confirm with your AHJ.
  • High-density batts: R-15 HD and R-21 HD are the same physical thickness as R-13 and R-19 respectively, but denser. They fit the same cavity and are the most common way to meet zone 4+ requirements without changing framing.
  • Local amendments: California (Title 24), Washington State, and several other states have adopted energy codes stricter than IECC. Always confirm with the local AHJ.
  • Thermal bridging: Stud framing reduces effective R-value by 15–20%. Some codes require continuous insulation to address this. Check your jurisdiction's requirements for CI specs.

Products We Stock for Each Zone

  • Zone 1–2: R-13, R-19, R-30 in stock
  • Zone 3: R-13, R-15, R-21, R-38 in stock
  • Zone 4: R-15 HD, R-21 HD, R-38, R-49 in stock
  • Zone 5: R-21 HD, R-49 in stock
  • Zone 6–8: R-21 HD, R-49 in stock — call for high-R attic solutions

Call (929) 466-1426 to confirm current stock and get a same-day quote for your project.

Calculate Bags Needed Get a Quote